Quality Management System
– Rajas has a strong QMS programme, approved by ‘TUV NORD’ in accordance with ISO 9001:2015
– Quality Policy & Safety Policy are defined by the organizations which are in line with ISO standard
Silent points of the system are, amongst other -
- Batch number identification from raw material to finished stage, auto-cad generated PDIR reports, thus ensuring no dimensions are missed
- Periodic inspections with calibrated equipment at various stages of production are recorded and analysed
- Process drawings and control plans for each process.
- One meeting on performance of the system every month at middle management level, and one meeting every quarter at top management level, thus ensuring that the entire organization is working together towards implementation of the system
Inspection Facilities
- Surface Plate : 1600 x 1000 mm
- Surface Plate : 600 x 500 mm
- Height Gauge: 0-600: 3 nos
- Dial Bore Gauges: 0-800 All sizes
- VernierCalipers: 0-200 ( 2 nos) , 0-300 ( 4 nos) , 0-600 (1 no), 0-1000 (1 no)mm
- Dial VernierCalipers: 0-300 mm – 5 nos
- Depth VernierCaliper: 0-300 mm – 5 nos
- Micrometers: 0-25, 25-50, 0-150, 150-300, 300-400, 400-500, 600-700, 700-800, 800-900, 900-1000 mm
- Ultrasonic Thickness Gauge: 1 no
- Dial Gauge with stand : 5 nos
- Trimos : 1 no